Skip to content

Monitor and operate runtime data on Windows

Read project configuration, monitor tags, alarms, trends, parameters, operation records, and diagnostics, and submit controlled changes when runtime rules allow.

  • Windows desktop
  • Licensed runtime points
  • Controlled writes
Operations
Tags128
Alarms3
Allowed256
Alarm reviewRuntime healthy
Product form Windows runtime client WPF · .NET 10
Runtime modules Tags · Alarms · Trends · Parameters Includes audit and diagnostics
License model By runtime points Over-limit blocks the runtime pipeline
Write boundary Controlled writes License, permission, rule, and target must allow it

Implemented core capabilities

Tag monitoring

Monitor current values, quality, timestamps, and runtime status from project tag data.

Alarm handling

Query current and historical alarms and review handling state in the runtime client.

Trend viewing

Review selected variables as live or historical trends when project data is available.

Parameter operation

View current and historical parameters and submit controlled writes only after validation.

Runtime audit

Search operation history and event records for troubleshooting and handover.

Diagnostic search

Filter and page application diagnostics inside the desktop runtime client.

A clear four-step path

  1. 1

    Sign in

    Enter an authorized runtime project.

  2. 2

    Monitor

    Review tags, quality, alarms, and license capacity.

  3. 3

    Operate

    Acknowledge alarms or submit allowed tag and parameter changes.

  4. 4

    Trace

    Use trends, audit records, and diagnostics to reconstruct events.

Where this product fits

  • Control-room monitoring
  • Equipment exception investigation
  • Controlled process-parameter adjustment
  • Shift handover and operational review

Licensing, requirements, and boundaries

Licensing and editions

By licensed runtime points

Operational capacity is controlled by the runtime-point allowance in the license.

Visible read-only fallback

When activation or policy blocks runtime, the shell can remain visible while acquisition and writes stay disabled.

Project-specific validation

Data quality and final write behavior depend on Gateway, devices, networks, and engineering configuration.

Technical requirements

  • Windows WPF desktop application targeting net10.0-windows.
  • Requires valid project configuration and available runtime data services.
  • Trend deployment currently uses SciChart-related components; target licensing must be confirmed.
  • Database capacity, retention, hardware, multi-screen, and continuous-runtime specifications remain project-specific.